low voltage panels
Showing all 6 results
SUB-MAIN DISTRIBUTION PANEL
Assembled with electrical protection components (MCCP, MCB, LBS, etc.)
We bear in mind the cable entry from top or bottom during the manufacturing process & additional interior space up to 25 % to facilitate connecting loads or adding any future loads. Sub-main panel Boards are part of low-voltage electrical systems used to divide an electrical power feed into subsidiary circuits; while providing overloads and short circuits protection. in a common, It has to be an indoor floor-standing enclosure.
Prisma
– Up to 4000A, Icw=85 KA – From 4 – IEC61439-1&2 – RAl 7047 – IP54 – Sheet Metal |
Spacial
– Up to 6300A, Icw=85 KA – From 4 – RAl 7035 – IP55 – Sheet Metal / Stainless steel |
Local MAM (MAP)
– Up to 6300A, Icw=85 KA – From 4 – RAl 7035 or upon request – IP54 – Sheet Metal / Stainless steel
|
POWER FACTOR CORRECTION PANEL
The power factor correction panels are used to improve the power factor in electrical systems while ensuring they remain energy and cost-efficient. It also can be used to decrease the harmonic of the network by adding reactors.
Panel Designed according to IEC 61921, IEC 60831
- Modular design, non-compartmentalized,
- Indoor, Floor standing, cable entry from bottom.
- Step protection Fuse
- Step switching
- Microprocessor-controlled relay
- Automatic switching option, Manual switching upon request
MAIN DISTRUBTION PANELS
Since the beginning of MAM, we have specialized in the manufacturing of Main Distribution Panels. We have manufactured many MDB up to 6300A and installed them in different locations such as tourism resorts, factories, hospitals, banks, and administrative buildings.
Main & sub-main Panel Boards are part of low-voltage electrical systems used to divide an electrical power feed into subsidiary circuits; while providing overloads and short circuits protection. in a common, it must be within an indoor floor-standing enclosure.
Prisma | Spacial | Local MAM (MAP) |
---|---|---|
Up to 4000A, Icw=85 KA | Up to 6300A, Icw=85 KA | Up to 6300A, Icw=85 KA |
From 4 | From 4 | From 4 |
IEC61439-1&2 | RAl 7035 | RAl 7035 or upon request |
RAl 7047 | IP55 | IP54 |
IP54 | Sheet Metal / Stainless steel | Sheet Metal / Stainless steel |
Sheet Metal |
FEEDER PILLAR & COFREE BOXES
A feeder pillar provides insulation to electrical distribution equipment at a local level, protecting both the cables and the transformer from faulty fuses. Feeder pillars allow for efficient local maintenance to your equipment, thereby reducing site downtime and overall maintenance costs.
General Specifications:
- Material: 1.5mm cold rolled
- Surface Treatment: Electrostatic painted with epoxy-polyester resin
- Paint finish: Light gray – RAL 7035 (otherwise upon request)
- Degree of Protection: IP54
- Installation: Free Standing
- Operation System: 3 Phase 50Hz, 380/200 Vac
- Rated current: Up to 630A
AUTOMATION PANELS
Automation Panels are used to monitor and control heavy-duty machinery in commercial and industrial settings. Automation control panels can perform both simple and complex processes by employing relays, timers, sensors, starters, controllers, and HMI. This technology allows for a hands-free approach that lets the user experience high efficiency, functionality, and flexibility with automation control panels. PLC control panels offer various options for a protocol which thereby increases their range of application
ATS
The nature of loads and electrical sources is determined by the specific
design and manufacturing process of these types of L.V. panels. Furthermore, we always adhere to international standards regarding this type of L.V. panel, including all electrical and mechanical protection regulations. Control circuits are constructed either using classic control circuits or using PLC.
Manual & Automatic Transfer Switch (MTS & ATS)
The transfer switch is used to switch a power supply from its primary source to a backup source. It can be either manual or automatic in sensing a failure or power outage in the primary source. When a primary power system malfunctions, the ATS invokes a standby power source, such as an uninterruptable power supply. An ATS is also capable of fueling long-term backup power systems, such as local diesel generators, to operate electrical equipment until utility power is restored.
Prisma
– Up to 4000A, Icw=85 KA – From 4 – IEC61439-1&2 – RAl 7047 – IP54 – Sheet Metal |
Special
– Up to 6300A, Icw=85 KA – From 4 – RAl 7035 – IP55 – Sheet Metal / Stainless steel |
Local MAM (MAP)
– Up to 6300A, Icw=85 KA – From 4 – RAl 7035 or upon request – IP54 – Sheet Metal / Stainless steel
|