Shop
Showing 1–12 of 22 results
SUB-MAIN DISTRIBUTION PANEL
Assembled with electrical protection components (MCCP, MCB, LBS, etc.)
We bear in mind the cable entry from top or bottom during the manufacturing process & additional interior space up to 25 % to facilitate connecting loads or adding any future loads. Sub-main panel Boards are part of low-voltage electrical systems used to divide an electrical power feed into subsidiary circuits; while providing overloads and short circuits protection. in a common, It has to be an indoor floor-standing enclosure.
Prisma
– Up to 4000A, Icw=85 KA – From 4 – IEC61439-1&2 – RAl 7047 – IP54 – Sheet Metal |
Spacial
– Up to 6300A, Icw=85 KA – From 4 – RAl 7035 – IP55 – Sheet Metal / Stainless steel |
Local MAM (MAP)
– Up to 6300A, Icw=85 KA – From 4 – RAl 7035 or upon request – IP54 – Sheet Metal / Stainless steel
|
RISER BOX – MOX
A Riser Box is a standard electrical box that houses and protects the connections of two or more circuit cables or wires. it’s common use in residential & commercial multi-floor buildings. MAM has A2 models of riser boxes according to the way of fixing the door.
Technical specifications:
Material: Cold rolled sheet steel
Surface treatment: Electrostatic painted with epoxy-polyester resin
Paint finish: Light gray – RAL 7035
Degree of protection: IP31
Installation: Flush Mounted
Cable entry: Bottom/ Top
User Access: Front
Thickness: 1 mm
Dimensions: As Per our Standard
POWER FACTOR CORRECTION PANEL
The power factor correction panels are used to improve the power factor in electrical systems while ensuring they remain energy and cost-efficient. It also can be used to decrease the harmonic of the network by adding reactors.
Panel Designed according to IEC 61921, IEC 60831
- Modular design, non-compartmentalized,
- Indoor, Floor standing, cable entry from bottom.
- Step protection Fuse
- Step switching
- Microprocessor-controlled relay
- Automatic switching option, Manual switching upon request
MAIN DISTRUBTION PANELS
Since the beginning of MAM, we have specialized in the manufacturing of Main Distribution Panels. We have manufactured many MDB up to 6300A and installed them in different locations such as tourism resorts, factories, hospitals, banks, and administrative buildings.
Main & sub-main Panel Boards are part of low-voltage electrical systems used to divide an electrical power feed into subsidiary circuits; while providing overloads and short circuits protection. in a common, it must be within an indoor floor-standing enclosure.
Prisma | Spacial | Local MAM (MAP) |
---|---|---|
Up to 4000A, Icw=85 KA | Up to 6300A, Icw=85 KA | Up to 6300A, Icw=85 KA |
From 4 | From 4 | From 4 |
IEC61439-1&2 | RAl 7035 | RAl 7035 or upon request |
RAl 7047 | IP55 | IP54 |
IP54 | Sheet Metal / Stainless steel | Sheet Metal / Stainless steel |
Sheet Metal |
ENCLOSURE SYSTEM MAF TYPE
Free Stand modular sheet steel enclosure for multi-purpose use
Technical specifications:
Operation voltage: 1150 Vac
Rated current: Up to 5000A
Rated frequency: 50/60 Hz
Short-time withstand capacity: 85KA
Material: Cold rolled sheet steel
Surface treatment: Electrostatic painted with epoxy-polyester resin
Paint finish: Light gray – RAL 7035
Degree of protection: IP42, IP54
Internal separation: From 1 to Form 4b
Cable entry: Top or Bottom
Door opening angel: 180°
Lock: 1 Rod latch system lock with 4 Hinges
User Access: Front / Rear
Thickness: 1.5 mm
Dimensions: As Per standard
FEEDER PILLAR & COFREE BOXES
A feeder pillar provides insulation to electrical distribution equipment at a local level, protecting both the cables and the transformer from faulty fuses. Feeder pillars allow for efficient local maintenance to your equipment, thereby reducing site downtime and overall maintenance costs.
General Specifications:
- Material: 1.5mm cold rolled
- Surface Treatment: Electrostatic painted with epoxy-polyester resin
- Paint finish: Light gray – RAL 7035 (otherwise upon request)
- Degree of Protection: IP54
- Installation: Free Standing
- Operation System: 3 Phase 50Hz, 380/200 Vac
- Rated current: Up to 630A
AUTOMATION PANELS
Automation Panels are used to monitor and control heavy-duty machinery in commercial and industrial settings. Automation control panels can perform both simple and complex processes by employing relays, timers, sensors, starters, controllers, and HMI. This technology allows for a hands-free approach that lets the user experience high efficiency, functionality, and flexibility with automation control panels. PLC control panels offer various options for a protocol which thereby increases their range of application
ENCLOSURE SYSTEM M3S TYPE
Compact stainless-steel enclosure for multi-purpose use suitable for medical, food industries and outdoor application
Technical specifications:
Operation voltage: 690 Vac
Rated current: Up to 250A
Rated frequency: 50/60 Hz
Short-time withstand capacity: 25KA
Material: Stainless steel
Degree of protection: IP54
Door opening angel: 120°
Lock: 1 turn lathes lock with 2 Hinges.
User Access: Front (1 Door)
Thickness: 1.5 mm
Dimensions: As Per standard
ENCLOSURE SYSTEM MAS TYPE
Free Standing Monoblock sheet steel enclosure for multi-purpose use
Technical specifications:
Operation voltage: 690 Vac
Rated current: Up to 630A
Rated frequency: 50/60 Hz
Short-time withstand capacity: 50 KA
Material: Cold rolled sheet steel
Surface treatment: Electrostatic painted with epoxy-polyester resin
Paint finish*: Light gray – RAL 7035
Degree of protection: IP54
Internal separation: From 1 to Form 2
Cable entry: Top or Bottom
Door opening angle: 120°
Lock: 1 Rod latch system lock with 3 Hinges. For 1000 Width & above, 1 Rod latch system lock with 6 Hinges
User Access: Front
Thickness*: 1.5 mm
Dimensions*: As Per standard
Reference | Width (mm) | Height (mm) | Depth (mm) | No. of Doors | Weight (KG) |
MAS601604000.9 | 600 | 1600 | 400 | 1 | 83 |
MAS601804000.9 | 600 | 1800 | 400 | 1 | 94 |
MAS602004000.9 | 600 | 2000 | 400 | 1 | 45 |
MAS801203000.9 | 800 | 1200 | 300 | 1 | 51 |
MAS801402500.9 | 800 | 1400 | 250 | 1 | 57 |
MAS801403000.9 | 800 | 1400 | 300 | 1 | 58.3 |
MAS801604000.9 | 800 | 1600 | 400 | 1 | 82 |
MAS801804000.9 | 800 | 1800 | 400 | 1 | 91 |
MAS802004000.9 | 800 | 2000 | 400 | 1 | 100.3 |
MAS1001203000.9 | 1000 | 1200 | 300 | 2 | 62 |
MAS1001403000.9 | 1000 | 1400 | 300 | 2 | 70.6 |
MAS1001404000.9 | 1000 | 1400 | 400 | 2 | 87 |
MAS1001604000.9 | 1000 | 1600 | 400 | 2 | 98.3 |
MAS1001804000.9 | 1000 | 1800 | 400 | 2 | 109 |
MAS1002004000.9 | 1000 | 2000 | 400 | 2 | 120 |
MAS1201604000.9 | 1200 | 1600 | 400 | 2 | 108 |
MAS1201804000.9 | 1200 | 1800 | 400 | 2 | 120 |
MAS1202004000.9 | 1200 | 2000 | 400 | 2 | 131 |
MAS601604000.9 | 600 | 1600 | 400 | 1 | 80 |
ENCLOSURE SYSTEM MAF TYPE
Free Stand modular sheet steel enclosure for multi-purpose use
Technical specifications:
Operation voltage: 1150 Vac
Rated current: Up to 5000A
Rated frequency: 50/60 Hz
Short-time withstand capacity: 85KA
Material: Cold rolled sheet steel
Surface treatment: Electrostatic painted with epoxy-polyester resin
Paint finish: Light gray – RAL 7035
Degree of protection: IP42, IP54
Internal separation: From 1 to Form 4b
Cable entry: Top or Bottom
Door opening angle: 180°
Lock: 1 Rod latch system lock with 4 Hinges
User Access: Front / Rear
Thickness: 1.5 mm
Dimensions: As Per standard
ENCLOSURE SYSTEM PRIMI TYPE
Flush sheet steel enclosure horizontal arrangement for miniature circuit breakers
Technical specifications:
Operation voltage: 230/415 Vac
Rated current: 63A
Rated frequency: 50/60 Hz
Short-time withstand capacity: 10 KA
Material: Cold rolled sheet steel
Surface treatment: Electrostatic painted with epoxy-polyester resin
Paint finish*: Light gray – RAL 7035
Degree of protection: IP31
Cable entry: Top or Bottom
Door opening angel: 120°
Lock: 1 sliding Lock with 2 rivet Hinges. For 3 rows & above, 2 turn lathes Locks & 2 rivet Hinges
User Access: Front
Thickness*: 1 mm
Dimensions*: As Per standard